Installation architecture
Parts are divided into four zones. Identifying the zone concerned is the first diagnostic reflex: it immediately narrows down the possible references.
Control cabinet
ARCA control boards and associated power supplies. The generation — ARCA II or ARCA 3 — determines the board reference.
Related parts: Arca board · power supply · cabinet
Shaft and selection
Magnetic fingers handle position detection. Their type differs by generation: CB and CS on ARCA 2, CDB on ARCA 3.
Related parts: magnetic finger · sensor · bistable
Car and landings
3G range buttons with engraving and braille, landing plates and position indicators.
Related parts: Arca button · plate · display
Machinery
The gearless version of ARCA 3 comes with a direct-drive machine and its encoder feedback.
Related parts: winch · encoder · brake
Points of attention
- Determine the generation before any order: the CB/CS magnetic fingers of ARCA 2 are not those of ARCA 3, which uses the CDB type.
- Control boards are specific to their generation and carry settings: a blank board does not replace a configured board.
- The Orona maintenance terminal is needed to restore the configuration after replacing a board.
- On 3G buttons, note the engraved symbol and the presence of braille: these elements fall under accessibility rules and are not optional on controls intended for users.
- Send a photo of the board and its markings: it is the most reliable way to tell apart two generations of similar appearance.
Get a quote
State the part reference if you know it, the number of levels and accesses of the unit, the type of wiring and your wilaya. A photo of the part in place and its markings confirms the match. KMY confirms the final price, availability and delivery time in Algeria.
Search all Orona ARCA parts in the catalogue ↗
Source of the specifications: Orona ARCA II controller configuration tool manual, standard 0466035 version 6 (26/11/2015), and ARCA 3 Gearless documentation. Data reproduced for information only; only the manufacturer’s documentation is authoritative. Specifications may change between versions.